| Coverage
SF/Gallon | Mixing Ratio | Penetration
Thickness Inches | Gallons
SoilShield-LS | Gallons Water | Gallons Mix
Solution | Total Area
Covered | 2" (Dry Condition) | | 140 | 1:30 | 2 | 1 | 30 | 31 | 140 | | 140 | 1:30 | 2 | 1 | 484 | 500 | 2,240 | | 140 | 1:30 | 2 | 48 | 1,452 | 1500 | 6,720 | | 140 | 1:30 | 2 | 129 | 3,871 | 4,000 | 18,060 | 2" (Moist Condition | | 140 | 1:20 | 2 | 1 | 20 | 21 | 140 | | 140 | 1:20 | 2 | 19 | 481 | 500 | 2,660 | | 140 | 1:20 | 2 | 58 | 1,442 | 1,500 | 8,120 | | 140 | 1:20 | 2 | 154 | 3,846 | 4,000 | 21,560 | 3" (Dry Condition | | 80 | 1:30 | 3 | 1 | 30 | 31 | 80 | | 80 | 1:30 | 3 | 16 | 484 | 500 | 1,280 | | 80 | 1:30 | 3 | 48 | 1,452 | 1,500 | 8,120 | | 80 | 1:30 | 3 | 129 | 3,871 | 4,000 | 21,560 | 3" (Moist Condition | | 80 | 1:20 | 3 | 1 | 20 | 21 | 80 | | 80 | 1:20 | 3 | 24 | 476 | 500 | 1,920 | | 80 | 1:20 | 3 | 71 | 1,429 | 1,500 | 5,680 | | 80 | 1:20 | 3 | 190 | 3,810 | 4,000 | 15,200 | Pedestrian Pathways | | 120 | 1:20 | 2 | 1 | 20 | 21 | 120 | | 120 | 1:20 | 2 | 24 | 476 | 500 | 1,930 | | 120 | 1:20 | 2 | 71 | 1,429 | 1,500 | 8,520 | | 120 | 1:20 | 2 | 190 | 3,810 | 4,000 | 22,800 | Top Coat For Maintenance Application | | 960 | 1:50 | 1 | 1 | 50 | 51 | 960 | | 960 | 1:50 | 1 | 10 | 490 | 500 | 9,600 | | 960 | 1:50 | 1 | 29 | 1,471 | 1,500 | 27,840 | | 960 | 1:50 | 1 | 78 | 3,922 | 4,000 | 74,880 |
| Color |
White to off white, Colorless when Cured. |
| Form |
Liquid |
| Weight |
9.4 Pounds per gallon |
| PH |
4 to 5.05 |
| Solids |
60% |
| Flammability |
Non-Flammable |
| Flash point open cup |
None |
| Storage Life |
Do not freeze. Repeated freezing and thawing will cause the
product to break down. |
APPLICATION RECOMMENDATIONS
Subgrade shall be shaped to the line and
grade required allowing for positive drainage on all surfaces to receive
shoilshield-ls. Subgrade shall be prepared and compacted as
specified prior to placement of aggregate materials. Subgrade shall then
be proof-rolled to identify any unstable area. Any wet or unstable
Subgrade should be repaired prior to the placement of aggregate and
SoilShield-ls. Apply cover aggregate loosely and evenly over subgrade to
the specified depth prior to SoilShield-ls application. When stabilizing
native soils without cover aggregate, the top 2 to3" should be loosened
evenly to allow full penetration. Eroded areas or rills should be
stabilized and compacted prior to surface treatment.
SoilShield-LS shall be applied evenly and
uniformly at the rate of one gallon concentrate per 120 to 140 square feet
diluted in water at a ratio of between 20:1 and 30:1. For steeper slopes,
heavy clay soils, roadways, heavily traveled trails, or critical sites, the
application rate should be increased to one gallon concentrate per 80 to 120
square feet diluted to 20:1 to 20:1. The actual dilution rate may be
varied based on existing moisture and optimum moisture of the material being
stabilized. Solution should be applied slowly enough to ensure full
penetration. This may require several light applications instead of one
heavy one. Allow enough time between sprays of solution to soak in
(percolate) to the full depth of the material to be stabilized. The area
should be raked, bladed or tilled between sprays for material to be mixed
thoroughly in granite or soil. Full penetration should be verified by hand
sampling prior to compaction. After Allowing Material to dry to a compactable
consistency (optimum moisture) roll and compact with a 3-1/2 ton steel drum or
heavy steel roller to specified compaction. On Dry, Hydrophobic soils,
spray water over the surface before application of SoilShield-LS. Water truck,
water wagon, or hydromulcher may be used for application.
Soilshield-LS as supplied in drums should be
protected from freezing, from outside storage and protected from direct sunlight
and temperatures above 80 degrees Fahrenheit.
Applications shall not be made during rain
or periods when rain may be expected during a 24 hour period. For best
curing of emulsion, application should not be made at temperatures lower than 40
degrees Fahrenheit. Treated area shall be protected from traffic until entire
thickness has completely dried. This could be 48 to 72 hours or more
depending on weather conditions. SoilShield-LS shall not be applied in high wind
to avoid property damage and to assure accurate coverage controll.
Manufactures training is recommended for
installers involved in the application of SoilShield-LS.
SOIL SHEILD STABILIZER 5 GAL. SOIL SHIELD 5 GAL
|