Application
These highly popular next-generation
anti-siphon valves, with built-in atmospheric vacuum breakers, offer the
ultimate in performance, reliability and ease-of-use for a wide variety of
residential applications.
|
2711APR
|
|
Features
- Rugged, double-beaded SANTOPRENE ©
diaphragm provides leak-proof seal
- Buna-N valve seat seal
- Manual internal bleed
- Manual external bleed (flush mode)
- Full stainless steel metering system
- Flow control allows precise flow
adjustment and manual shut-off
- Gravity-type anti-siphon poppet
- Heavy-duty, corrosion-and UV-resistant
PVC, glass-filled polypropylene and stainless steel construction
- Encapsulated injection-molded solenoid
- Captive hex plunger
- Easily serviced without removal from
system
- Electric H-body atmospheric vacuum
breaker
- Meets listing standards of ASSE, IAPMO
and CSA
APR Models
- Captured hex/Phillips screws
- Removable, ergonomic tamper-resistant
flow control handle
- Self-aligning bonnet permits fast and
easy servicing
- High-strength ribbed bonnet
- Patent pending floating metering
system
DPR Models
- Threaded bonnet system permits fast
and easy servicing
- Patented, tamper-resistant flow
control mechanism
Operating
Specifications
- Flow range: 5-30 GPM
- Pressure range: 10-150 psi
Electrical
Specification
- Solenoid: 24 VAC
- Inrush volt-amp: 24 VAC-11.50 VA
- Inrush current: .4 amp
- Holding volt-amp: 24 VAC-5.75 VA
- Holding current: .2 amp
|
Optional Accessories
- Threaded bonnet wrench (2400-45: DPR
models)
DC latching solenoid (E2002)
- Note: Maximum pressure for a valve
that utilizes E2002 latching solenoid is 120 psi.
- Reclaimed water solenoid kit
- (RW60-Kit); purple solenoid with
purple warning tag
Dimensions
2711
Models
- Height:
5-5/8"
- Width:
3"
- Length:
6-1/4"
2713
Models
- Height:
6"
- Width:
3"
- Length:
6-7/8"
2713DPR
Models:
How to Specify
|
Model
|
Size |
Threaded
Bonnet / Stainless Steel Screws Options
|
| 2711APR |
3/4" |
ss |
| 2713APR |
1" |
ss |
| 2711APR |
3/4" |
tb |
| 2713APR |
1" |
tb |
Note: Anti-siphon valve is
to be mounted above ground at least 6" above highest sprinkler head
(consult local codes)
|